Is it possible to install an elevator at the entrance of unit building?

Your current location: Home >> News >> knowledge

Is it possible to install an elevator at the entrance of unit building?

Date of release:2018-08-27 Author: Click:

Is it possible to install an elevator at the entrance of unit building?


The fire exit is at the gate of the unit building. Can we add an elevator? This problem, in the jinsha university community has been heated discussion.


The jinsha university community on route 6 has a total of 60 buildings, two of which are small high-rise buildings with elevators, and the rest are six and a half stories without elevators. Since January this year when the elevator installation work began, frequent visits to this old community has become the normal work of the construction (housing management) bureau of the development zone.


"It is not easy to install an elevator because it requires the consent of all the owners." The development zone construction (housing management) bureau staff introduced, in this process will exist many problems, mainly is the high and low floor of the opinion is not uniform, especially the daylighting, ventilation, capital allocation, will become the dispute focus, and some technical issues. "When something goes wrong, we usually go to the door and coordinate."


This time they came to the community, mainly aiming at technical problems. It turns out that the residents of unit 1 of building 5 of jinsha university all agree to install the elevator, but there is a 4.2-meter wide road at the door, and this road happens to be the fire exit, which brings the problem of installing the elevator. Once the elevator is installed, it takes up the fire escape. Officials from the development zone construction (housing management) bureau said they specially invited people from several departments to see if they could work out a solution.


It was suggested that there was a green field just west of the five buildings, which could be used to build the elevator. However, the plan was quickly rejected because the elevator would only be accessible to five families on the west side, and five families on the east side would have to pass through the west side if they wanted to use the elevator. "Is it possible to connect through the corridor bridge?" The proposal was eventually rejected. From the greenfield arch bridge to the unit corridor, you need to set the supports for the supports at the position of the gate of the five units. In this way, it will affect the clear width of the fire path in the community. The group discussed several more options, all of which were eventually abandoned for inappropriateness. "We've thought about all the ways we could," he said. Development zone construction (housing management) bureau staff said.